Page 19
11 FAQ and Troubleshooting
Q: I don’t see any status lights on at all.
A: Make sure the power cable is correctly plugged into the
unit and make sure the power supply is plugged into the
wall.
Q: Red status light is flashing red.
A: Make sure the network cable is plugged into the unit.
The status light on the jack indicates if you are connected
to the network or not. You can also ping the device to see
if it’s on your network.
Q: How do I ping the Barix Instreamer to see if it’s on my
network?
A: You can ping any device on your network by opening a
DOS command box.
Type ping and the IP address of the unit to see if you can
get a response.
Example: ping 192.168.2.10
The proper response would be to see the message “reply
from 192.168.2.10”.
If you see the message “request timed out”, it means that
the Barix Instreamer is not on your network or that you
have entered the wrong numbers for the IP address.
Q: When I type in the IP address into the browser I get a
“This Page Cannot Be Displayed” Message
A: This means that you cannot connect to the Barix
Instreamer. There could be a couple of different reasons.
Make sure you are typing in the IP address correctly.
Check the cables to make sure the Barix Instreamer is
properly connected to the network.
Q: Will the Barix Instreamer work on my operating
system?
A: The Barix Instreamer works on virtually any operating
system, to control the Barix Instreamer a standard web
browser is all you need.
12 Technical specifications
Audio Format:
MP3 from 8 up to 192 kBit VBR (Variable Bit Rate)
Stereo/Mono
Audio Interfaces:
Stereo Line In (RCA 2Vpp max, level)
Headphone Out (3.5 mm Jack, 4.2Vpp max)
S/PDIF In (optical and RCA coaxial)
volume, bass and treble adjustable by browser
Network Interface:
RJ45 10/100 Mbit Ethernet (Auto), TCP/IP,
UDP, ICMP, DHCP, AutoIP, SonicIP
®, IPzator,
Integrated web server for control and configuration
Control Interfaces:
DSub 9pin male, 9600 Baud 8, N, 1
Miscellaneous:
Two LED (red and green) status indicators
Reset/Factory default button
Power requirements:
12 VDC 0.5 A, 230 VAC (EC) or
110 VAC (US) power supply included
Case:
Aluminum, 390 grams
6.5" x 1.5" x 5"
165 mm x 38 mm x 127 mm
Environmental conditions:
Temperature: 32 ~ 104° F / 0 ~ 40° C
Humidity: 0 ~ 70% relative humidity non-condensing
Certifications:
FCC A, CE A
User Interface:
Browser based (integrated web server),
serial port or Ethernet control API for home
automation systems